High Voltage Test Equipment

  • GDSD-140  Dielectric Strength Test Set For Insulation Sample

    GDSD-140 Dielectric Strength Test Set For Insulation Sample

    GDSD-140 test device is mainly suitable for making breakdown strength and withstand voltage test of solid insulating materials (such as: plastic, rubber, laminated materials, films, resins, mica, ceramics, glass, insulating paint and other insulating materials and insulating parts) under power frequency voltage or DC voltage.

    The electronic control system of the device is controlled by PLC, and the data collection method is photoelectrically isolated, which effectively solves the anti-interference problem in the test process. The man-machine operation is convenient, and the dynamic curve can be displayed in real time.

  • GIT-450kVA/150kV PD-free AC Dielectric Test Set

    GIT-450kVA/150kV PD-free AC Dielectric Test Set

    The GIT-450kVA/150kV PD-free AC Dielectric Test Set is an advanced automatic withstand voltage tester designed in accordance with the latest national power industry standards. It utilizes PLC controller technology, 2.4G ISM networking, and an advanced human-machine interface. This test equipment is suitable for power frequency withstand voltage testing and partial discharge testing of high-voltage electrical equipment of 150kV and below.The max. capacitance of tested object is 0.05μF at 150kV.

  • GDYT-10/100  Partial Discharge Testing System 10kVA/100kV

    GDYT-10/100 Partial Discharge Testing System 10kVA/100kV

    This set of equipment is mainly used for partial discharge measurement and other scientific experimental research.

  • GDZG-S DC Hipot Test Set

    GDZG-S DC Hipot Test Set

    GDZG-S series is equipment of testing DC voltage and DC leakage current of water-cooled generator in the situation of water through, which completely overcome the problems of long blow water time, bottom water hard to dry, easy to cause arcing within the coil. The device is light, simple wiring, and easy to read. Polarization compensation voltage is output directly by the case.

  • Partial Discharge Test System GIT series

    Partial Discharge Test System GIT series

    GIT series is widely used for high voltage, big capacity GIS power equipment insulated withstand voltage test, partial discharge test and GIS transformer accuracy test, suitable for GIS substation, GIS power equipment manufacturer, basin type electrical insulator manufacturer.

     

     

     

     

     

     

  • GDYD-55D AC/DC Hipot Test Set

    GDYD-55D AC/DC Hipot Test Set

    GDYD series AC/DC Hipot Test Set is composed of manual control unit and dry testing transformer (HV unit) which output AC voltage smoothly. When adding a HV diode, it can output DC voltage. Meanwhile, it has many monitoring and protection functions. 

  • GDYD-53D 50kV AC DC Dielectric Test Equipment

    GDYD-53D 50kV AC DC Dielectric Test Equipment

    AC hi-pot testing is the effective and direct way to test insulation strength for electrical equipment, apparatus, or machines. It checks dangerous flaws which assure electrical equipment continuous working.

     

  • GDFR-C1 Series AC/DC High Voltage Divider

    GDFR-C1 Series AC/DC High Voltage Divider

    GDFR-C1 series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. It consists of voltage divider and measurement instrument.

     

     

     

  • GDYD-63A Versatile AC/DC Hipot Test Set for Comprehensive Electrical Testing

    GDYD-63A Versatile AC/DC Hipot Test Set for Comprehensive Electrical Testing

    GDYD-63A AC/DC Hipot Test Set is composed of automatic control unit and AC oil testing transformer (HV unit) which output AC voltage smoothly. Meanwhile, it has many monitoring and protection functions. When the short circuit rod of testing transformer is taken out, the output is DC voltage.

  • GDYD-2030A 30kVA.200kV Automatic AC/DC Hipot Test Set

    GDYD-2030A 30kVA.200kV Automatic AC/DC Hipot Test Set

    GDYD-2030A Automatic AC/DC Hipot Test Set is composed of automatic control unit and gas testing transformer (HV unit) which output AC or DC voltage smoothly. Meanwhile, it has many monitoring and protection functions.

  • GDFR-D1 AC/DC High Voltage Divider

    GDFR-D1 AC/DC High Voltage Divider

    GDFR-D1 Series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. The digital meter and divider are equipped in one unit.  

  • VLF-Series Portable VLF Hipot Test System with Advanced Safety Features

    VLF-Series Portable VLF Hipot Test System with Advanced Safety Features

    The VLF Hipot Test System are truly compact and portable VLF test sets that determine the insulation condition of medlum voltage cables. Both test sets perform VLF and Dc testing, as well as sheath testing with sheath fault location possibilities.Its design complies with the international standard IEEE 400.2-2013.The VLF Hipot Test system combine a small and light weight VLF test set with integrated Tan Delta and Partial Discharge diagnostic modules to expand into a complete cable diagnostic system.

1234 Next > >> Page 1 / 4

Send your message to us:

Write your message here and send it to us